Transfusion and Apheresis Science
Volume 35, Issue 2 , Pages 125-130, October 2006

Error management of emergency transfusions: A surveillance system to detect safety risks in day to day practice

  • Martin Schmidt-Hieber

      Affiliations

    • Medizinische Klinik III (Hämatologie, Onkologie und Transfusionsmedizin), Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 30 8445 2310; fax: +49 30 8445 4468.
  • ,
  • Ronny Schuster

      Affiliations

    • Medizinische Klinik III (Hämatologie, Onkologie und Transfusionsmedizin), Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany
  • ,
  • Axel Nogai

      Affiliations

    • Medizinische Klinik III (Hämatologie, Onkologie und Transfusionsmedizin), Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany
  • ,
  • Eckhard Thiel

      Affiliations

    • Medizinische Klinik III (Hämatologie, Onkologie und Transfusionsmedizin), Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany
  • ,
  • Werner Hopfenmüller

      Affiliations

    • Institute for Medical Statistics, Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany
  • ,
  • Michael Notter

      Affiliations

    • Medizinische Klinik III (Hämatologie, Onkologie und Transfusionsmedizin), Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany

Received 14 February 2006; received in revised form 25 May 2006; accepted 1 June 2006.

Abstract 

Acute hemolysis due to AB0-incompatibility caused by transfusion of red blood cell concentrates (RBCC) to the wrong recipient is one of the major causes of transfusion-related death. As part of our policy to improve quality and safety in emergency transfusion, we have developed a standardized surveillance system for supplying RBCC in emergency situations. This surveillance system involves the implementation of a standardized set of basic data transmitted from the requesting unit to the blood bank by phone and a scoring system to check for compliance with guidelines and errors in daily routines. Communication deficiencies and delayed pretransfusion sampling were the most common errors.

Keywords: Emergency transfusion, Error management, Surveillance, Mistransfusion

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1473-0502(06)00111-X

doi:10.1016/j.transci.2006.06.001

Transfusion and Apheresis Science
Volume 35, Issue 2 , Pages 125-130, October 2006